Since 2006, our organization has gaining appreciation as the topmost manufacturer, exporter and supplier of Electrical Control Panels. The offered panels are ideal for a wide number of machinery and industrial plants to control and monitor the operations. These panels are designed and assembled with utmost precision using quality-approved components and sophisticated techniques in adherence with international quality standards. Stringently tested on defined quality parameters, the provided Electrical Control Panels can be availed from us in several specifications at negotiable prices.
Features:
Maximum synchronous alarm of each host:
Further Details:
Power components
Power components manage and control the flowing of electrical power.
Circuit Breakers
A circuit breaker is a hand-operated electrical power switch, which can identify and detect short circuit and overload premises by turning itself Off when one of these preconditions is recognized. Short circuit stipulations are perceived magnetically whereas overload conditions are perceived thermally.
Fused Disconnects
A Fused Disconnect is the grouping of a fuse and an automatic functioned electrical power switch. A fuse is an attenuated metal wire in a sand compact paper wrapper. A fuse interrupts the flowing of electrical power when short circuit or overload origins the metal wire to figuratively burn up. A fuse breaks the flow rate of electrical power by fluent and graceful self termination.
Motor Starters
A Motor Starter is an appliance or assemblage of devices (Contactor, Circuit Breaker, Overload Relay), which are used to control and power a motor. It specifically includes an Overload Relay and Contactor to direct and manage the motor, but these can be supplanted by a Soft Starter or Variable Frequency Drive so as to modify the motor control.
Soft Starters
A Soft Starter is an uncomplicated solid state motor power controller. Instead of merely opening and closing the power circuit same like a motor contactor, it inclines the motor voltage up or down so as to make the turning of motor in 'on' and 'off' more easily and eliminates electrical rushes and mechanistic shocks. A Soft Start (SS) is more high-priced than a motor contactor, but gives the appended benefit of reduction in electrical and mechanical dazes connected with starting and stopping of motor.
Variable Frequency Drives
A Variable Frequency Drive (VFD) is a modern solid state power controller. Instead of just building the motor voltage up and down similar to a soft start to twist the motor on and off, a Variable Frequency Drive (VFD) powers the motor velocity and speed at all period of time. A Variable Frequency Drive (VFD) is more costly than a Soft Start (SS), but furnishes the extra performance of controlling motor speed.
Control components
Control components handle the logical operating series. Below are the elementary descriptions for leading control part types.
Control Relays
A Control relay is the simplex electrical control instrument. It includes a coil that can be affected (logical 1) and de-energized (logical 0) by an electric voltage (120V, 24VDC, etc.) and connections that change logic state founded on its coil (logic input) state. Control relays are utilized to turn other instruments (pilot lights, contactors, etc.) on and off.
Timing Relays
A Timing relay is the next easiest control device. These are the control relays with built-in timekeepers to control when their connections change state, and are utilized for turning other devices (pilot lights, contactors, etc.) on and off at particular times.
ON TIMER – Contacts turn to 'On' state after ON pause when coil is stimulated.
OFF TIMER – Contacts turn to 'Off' state after OFF delay when coil is de-energized.
ONE SHOT TIMER – Contacts turn and stay in 'On' state for ON time when coil is affected.
REPEAT CYCLE TIMER – Contacts frequently change states (On / Off) when coil is aroused.
Programmable Logic Controllers
A Programmable Logic Controller is a grouping of parts (timers, relays etc.) in a collection. PLCs are packaged in different sorts and can reach in price from under $100 to various thousand dollars. They are supple and permit communications between the people with computer skills and programming tools such as computer, software, cables, etc. so as to arrange them to function decently and precisely in every application.
Specification
Features | Contents |
Suitable Power | 0.75~7.5KW (Please refer to the label on the controller) |
Equipment Dimension | 385x240x150mm |
Control Method | Manual control/Auto control |
Liquid Level Control Method | Floating ball switch/electrode probe/ remote pressure gauge/pressure switch/flow rate switch |
Voltage | Three-phrase AC380V Single-phrase AC220V |
Frequency | 50HZ/60HZ |
No-load(dry running)Guard Time | 20s |
No-load Failure Restart Time | 0~999 minute,could be changed, default vale is 30 minutes |
Over-load Guard Time | 5sX6 min(inverse-time characteristic: the greater current, the shorter time) |
Block-up Time | 1.5s |
Over Pressure/ Low Pressure Time | 5s,recovery time:20s |
Over Pressure/ Low Pressure Voltage | Three-phrase 380V, over pressure/low pressure voltage450V/350V Single-phrase 220V, over pressure/low pressure voltage250V/180V |
Phrase Sequence Guard Time | 3s |
Phrase Default Time | 3s |
Current Unbalance Guard time | 3s |
Rustproof Inspection | Support |
Power Consumption | Static power: 4W Dynamic Power: 8W |
Overload Output Alarm | Sound-light alarm, optional BA dry contact:AC250V 5A, DC30V 5A |
Liquid-level Control Transmission Distance | 500m |
Remote Communication | Optional RS485 |
Installation Component | EASYINSTALL hidden installation component, more convenient installation,more beautiful appearance. |
Shell Material | Engineering plastics |
Protection Grade | IP54 |
Installation Condition | Indoor or outdoor, avoid direct exposure in the sun or getting wet in the rain |
Operating Environment: | |
Temperature: | 10 degree to +55 degree |
Relative Humidity | less than 95% (40 degree, non-condensing) |
AC Power: | 220VAC, 50Hz, 3A |
DC Power: | 24VDC, 7.0Ah |
Pump Electric Control Panel - Manufaturer | |
Metal Box: | CRC Sheet with Powder coated. |
Contractor: | Schneider, BCH (Reputed). |
MCB/MCCB: | Schneider, BCH, Technic, C&S, (Reputed) |
Digital Ammeter (0 - 30 Amps) R-Y-B: | Kaizen. |
Digital Voltmeter (0 - 500 Volt) RY-YB-BR: | Kaizen. |
Over Load Protection (As per Motor Rating): | Variable with 0 to 60 Sec Time |
Under Load Protection : | Variable with 0 to 60 Sec Time. |
Over Voltage Protection: | Variable with 0 to 60 Sec Time. |
Under Voltage Protection | (300 - 500 Volt) Variable with 0 to 60 Sec Time. |
Single Phase Preventer with | Current and Voltage Sensing. |
Switch - | Auto-Manual. Fire alarm: 500 Feedback: 500 Trouble: 500 |
Power and Control wiring: | Cupper. |
Indicating Lamp: | R-Y-B (22.5 sq.mm LED Type). |
Push Button: | On/Off (22.5 sq.mm LED Type). |
Packaging & Delivery